Building a PLC Program That You Can Be Proud Of – Part 6

We will continue the series by looking at a sequencer controlling seven cylinders that can be taught. The cylinders can be operator programmed from the AdvancedHMI screen. You will be able to select what cylinders to activate at each step and program in 500 steps. Our PLC will be the Do-More from Automation Direct.

Here is a quick review of the programming series so far. If you are new to the site, we recommend reviewing the other parts in the series first.
In part 1 we looked at writing PLC programs to control a traffic light using discrete bits and then using timed sequencing using indirect addressing.
Part 2 used indirect addressing for inputs as well as output to control the sequence of pneumatic (air) cylinders in the program. Part 3 and 4 we returned to the traffic light application and expand our program significantly. We looked at the sequence of operation using Input, output and mask tables.
In part 5 we used the AdvancedHMI software to create the game of Simon. A round in the game consists of the device lighting up one or more buttons in a random order, after which the player must reproduce that order by pressing the buttons. As the game progresses, the number of buttons to be pressed increases.

We will be using AdvancedHMI to communicate Modbus TCP to the Automation Direct Do-More Designer Software Simulator. The following is the sequence of operation:
Watch on YouTube : Running the Cylinder Sequence (PLC / HMI)
Note: All of the  programs used are provided free of charge and are an excellent way to learn PLC / HMI programming.

The following table is the Modbus TCP memory map to the Do-More PLC:

Coil/Register Numbers Data Addresses Type Do-More PLC Table Name
00001-09999 0000 to 270E Read-Write MC1 to MC1023 Discrete Output Coils
10001-19999 0000 to 270E Read-Only MI1 to MI1023 Discrete Input Contacts
30001-39999 0000 to 270E Read-Only MIR1 to MIR2047 Analog Input Registers
40001-49999 0000 to 270E Read-Write MHR1 to MHR2047 Analog Output Holding Registers


Here are the inputs and outputs we will be using for our program:

Device Data Addresses Type Do-More PLC Description
Start Pushbutton 00011 Input MC11
Stop Pushbutton 00012 Input MC12
Jog Pushbutton 00013 Input MC13
Reset Pushbutton 00014 Input MC14
Run/ Jog Selector 00008 / 00015 Input/ Output MC8 / MC15  MC8 is the value and MC15 is the click
Light Stack 00010 / 00009 / 00008 Output MC10 / MC9 / MC8  Red / Green / Amber
Set Pushbutton 00071 Input MC71
Jog / Teach Selector 00070 Input MC70  MC70 on is teach mode
Sequence Step (Panel Meter) 40001 Output MHR1  Current step in the sequence
Inputs Actual 40002 Input MHR2  Show the actual inputs in binary format
Output Sequence 40003 Output MHR3  Show the actual outputs in a binary format
Input Sequence 40004 Input MHR4  Show the input sequence bits in a binary format
Cylinder 1 to 7 – value 00001 to 00007 Output MC1 to MC7  Determine if cylinder is on/off
Cylinder 1 to 7 – set (click) 00041 to 00047 Input MC41 to MC47  Set the cylinder button
Cylinder 1 to 7 – retract indicators 00021 to 00027 Input MC21 to MC27 Indicate cylinder has retracted
Cylinder 1 to 7 – extend indicators 00031 to 00037 Input MC31 to MC37 Indicate cylinder has extended
Cylinder 1 to 7 – extend / retract error indicators 00050 to 00063 Output MC50 to MC63 Indicate cylinder input error when jogging

The first thing we will do is design the HMI. We have three main areas on the screen. Basic Controls, Cylinder Visualization and the Sequence Step/Teach area. Please refer to the above reference chart for the inputs and outputs programmed on the screen.

Basic Controls:
This area will allow us to see what mode we are in via the stack light. Red – Stop
Yellow – Jog / Teach Mode – Troubleshooting
Green – Run

Cylinder Visualization:
Each cylinder will have indication lights to determine status of the cylinder. (Extended / Retracted)
The cylinder will also have red indication lights to reflect the differences between the current sequence and the next sequence step. This is visible when we are in jog mode.

Sequence Step/Teach:
When in jog or teach mode the sequence step is visible, which indicates the current step that we are on. The inputs and outputs are displayed as a binary value which represents the actual inputs and outputs. This is valuable when troubleshooting and finding errors in the system. The set button is visible when in teach mode. When pushed the outputs and inputs are set for that step and the sequence will then increment.

The following is the code for each of the words that the DataScribers are reading. This includes the code to change the word into a 16 bit binary value.

Private Sub DataSubscriber1_DataChanged(sender As Object, e As Drivers.Common.PlcComEventArgs) Handles DataSubscriber1.DataChanged
'Label1.Text = Hex(DataSubscriber1.Value)Dim i As Integer = DataSubscriber1.Value
Label1.Text = Convert.ToString(i, 2).PadLeft(16, "0") '16 bits
End Sub
Private Sub DataSubscriber2_DataChanged(sender As Object, e As Drivers.Common.PlcComEventArgs) Handles DataSubscriber2.DataChanged
'Label2.Text = Hex(DataSubscriber2.Value)
Dim i As Integer = DataSubscriber2.Value
Label2.Text = Convert.ToString(i, 2).PadLeft(16, "0") '16 bits
End Sub
Private Sub DataSubscriber3_DataChanged(sender As Object, e As Drivers.Common.PlcComEventArgs) Handles DataSubscriber3.DataChanged
Dim i As Integer = DataSubscriber3.Value
Label3.Text = Convert.ToString(i, 2).PadLeft(16, "0") '16 bits
End Sub
Private Sub DataSubscriber4_DataChanged(sender As Object, e As Drivers.Common.PlcComEventArgs) Handles DataSubscriber4.DataChanged
If DataSubscriber4.Value = True Then
     Label1.Visible = True
     Label2.Visible = True
     Label3.Visible = True
     Label4.Visible = True
     Label5.Visible = True
Else
     Label1.Visible = False
     Label2.Visible = False
     Label3.Visible = False
     Label4.Visible = False
     Label5.Visible = False
End If
End Sub

We will now look at the PLC ladder program. The program is broken down into several parts as follows:

ACC Automation
This is the main start / stop circuit of the program.
If we are in run mode the green light will be on. (MC9)
If we are not in jog mode (MC8) this circuit will be functional.

If we are not run mode (MC9) or in jog mode (MC8) then the stop mode is active.
This will turn on the red light. (MC10)

Run / Jog – Toggle Circuit
Flip Flop circuit to set the jog function

Move the outputs to the physical outputs when we go to run mode.

Indirect Addresses for the Program
V0 – Input pointer – 100 – 499
V1 – Output pointer – 500 – 999
V2 – Input pointer last step in sequence
V3 – Output pointer last step in sequence
V10 – Inputs to the sequencer
V20 – Outputs from the sequencer

Jog Mode – Jog Pushbutton

Reset the sequencer pointers. This will happen automatically in run mode or by hitting the reset button in jog or stop mode.

Teach Function
This first rung will activate the values so we can manually turn them off/on with the HMI screen.

This will reset the pointers when going into teach mode.

This will set the teach point and increment to the next step.

Show the current step of the sequence.
Note: 0 is the first step

Set the inputs for cylinders.
The actural physical input points would be inserted here.
HMI inputs from the cylinders have a 500ms delay to simulate the movement of the actual cylinder.

Set the actual inputs / sequencer inputs / sequencer outputs so we can monitor this on the HMI.

Set the outputs for cylinders.
This will set the physical output points Y1 to Y7.
This will also set the HMI cylinders MC1 to MC7 (00001 to 00007)

Diagnostic Bits for indicating the difference for the inputs to the PLC. This will show up as a red indication light on the cyclinder represented on the HMI.

This section of PLC logic will mimic the inputs from the cylinders.
Cylinder 1 – Retract MC21 (00021) – Extend MC31 (00031)
Cylinder 2 – Retract MC22 (00022) – Extend MC32 (00032)
Cylinder 3 – Retract MC23 (00023) – Extend MC33 (00033)
Cylinder 4 – Retract MC24 (00024) – Extend MC34 (00034)
Cylinder 5 – Retract MC25 (00025) – Extend MC35 (00035)
Cylinder 6 – Retract MC26 (00026) – Extend MC36 (00036)
Cylinder 7 – Retract MC27 (00027) – Extend MC37 (00037)

Between each funtion of the cylinder there is a time delay for the input to turn on and off of 500msec.

Cylinder 2 – Retract MC22 (00022) – Extend MC32 (00032)

Cylinder 3 – Retract MC23 (00023) – Extend MC33 (00033)

Cylinder 4 – Retract MC24 (00024) – Extend MC34 (00034)

Cylinder 5 – Retract MC25 (00025) – Extend MC35 (00035)

Cylinder 6 – Retract MC26 (00026) – Extend MC36 (00036)

Cylinder 7 – Retract MC27 (00027) – Extend MC37 (00037)

This is the end of the PLC program. You can see that the program is not very complicated once you break down the individual steps.

Download the PLC program and the Bin directory for the AdvancedHMI screen.

Watch on YouTube : Building a PLC Program that You can be Proud Of – Part 6b – Explaining the Program
If you have any questions or need further information please contact me.
Thank you,
Garry



If you’re like most of my readers, you’re committed to learning about technology. Numbering systems used in PLC’s are not difficult to learn and understand. We will walk through the numbering systems used in PLCs. This includes Bits, Decimal, Hexadecimal, ASCII and Floating Point.

To get this free article, subscribe to my free email newsletter.


Use the information to inform other people how numbering systems work. Sign up now.

The ‘Robust Data Logging for Free’ eBook is also available as a free download. The link is included when you subscribe to ACC Automation.

Excel Conditional Movement of Data

I have been recently asked how you can move data conditionally on an excel spreadsheet once the information has been obtained from the PLC? Monthly data was being collected from the PLC and put on an excel spreadsheet using Omron CX-Server DDE. They wanted at the beginning of each month to move the data to the appropriate month so they can track the changes.

The following three blogs were posted on how to get data into the Microsoft Excel Spreadsheet from the programmable logic controller. (PLC)

HOW TO IMPLEMENT MODBUS TCP PROTOCOL USING VBA WITH EXCEL

IMPLEMENTING THE OMRON CX SERVER DDE AND EXCEL

HOW TO IMPLEMENT THE OMRON HOST LINK PROTOCOL PART 2 – VBA

The method to move the data around the spreadsheet once the data has been obtained will be done by Visual Basic for Applications. (VBA)

Make a spreadsheet in excel as follows:

Operation:
When the current data in A2 or B2 changes, it will trigger a macro to execute. This macro will use the Worksheet_Change to trigger the code. The date in A2 is then compared to all of the dates located from A5 to A30. If a match is found then the value in B2 is placed beside the matching date found column. Example: A2 = A7 then B7 = B2
Here is a look at the VBA editor and code:

Here is the following code:
Private Sub Worksheet_Change(ByVal Target As Range)
If Target.Address = “$A$2” Or Target.Address = “$B$2” Then
For x = 5 To 30
If Sheets(“Sheet1”).Range(“A2”) = Sheets(“Sheet1”).Range(“A” & x) Then
Sheets(“Sheet1”).Range(“B” & x) = Sheets(“Sheet1”).Range(“B2”)
End If
Next ‘x
End If
End Sub

Download the example excel file.

Watch on YouTube : Excel Conditional Movement of Data
If you have any questions or need further information please contact me.
Thank you,
Garry