Implementing the Omron Host Link Protocol (VB.Net)

Previously we used VB6 (Visual Basic 6) to implement the Omron Host Link Protocol to communicate to our programmable logic controller. (PLC) In part 2 we used Visual Basic for Applications (VBA) to accomplish our host link serial communication. We will now look at using VB.Net to establish and retrieve information in and out of the PLC using host link. (C mode commands)

Hostlink communication protocol is a method developed by Omron for communication to PLC’s and other equipment. This ASCII based protocol is used over RS232 or RS422/RS485. It is a many to one implementation which means that you can communicate with up to 32 devices back to a master. (1:N) This communication on the industrial floor can control PLC’s, Temperature Controllers, Panel Meters, etc.

The Omron CP1H plc will be used with a CP1W-CIF11 (RS485) communication serial link adapter. We will also use a USB-485M Universal Serial Bus to RS485 adapter from automation direct. The video at the end of this post will demonstrate the communications by reading 10 registers form the DM area of the PLC. Continue Reading!

Omron CP1H Establish Communication

The Omron CP1H series of programmable logic controllers is programmed from CX-Programmer. CX-Programmer is part of Omron CX-One Factory Automation Integrated Tool Package. We will now establish communication to our CP1H PLC using CX Programmer. We will be using the USB connection (Built into the CPU) as well as a RS485 connection using the CP1W-CIF11 module. The Start Stop and Jog circuit that we developed last time will be transferred to the PLC unit. We will then verify that the program in the PLC is the same as the program logic in CX Programmer. Continue Reading!

Omron CP1H System Hardware

The Omron CP1 series of programmable logic controllers consist of three different units. CP1E is the cost effective unit, CP1L is the high performing controller that can come with embedded Ethernet and the CP1H is the position control and comprehensive programmable logic controller.
We will be looking a the CP1H for this series, but a majority of the information can be applied to the CP1E and the CP1L controllers as well.
Let’s start by looking at the CP1H hardware.

The CP1 series is designed with the same basic architecture as the CS and CJ Series. The special I/O units and CPU bus units of the CJ series can then be used. Always use CPM1A expansions units and CPM1A expansion I/O units when expanding the I/O capacity. The following diagram indicates the position of the unit with respect to the CJ and CS series. Continue Reading!

Omron C20K, C28K, C40K, C60K Troubleshooting

The Omron C20K, C28K, C40K and C60K shoebox programmable logic controllers have been discontinued since March of 2002. These ‘K’ series PLCs were a popular controller and have been in installations for over 25 years. We will take a look at this PLC and review some troubleshooting techniques. Planning for the eventual fatal failure of the CPU will also be discussed. Continue Reading!

Excel Conditional Movement of Data

I have been recently asked how you can move data conditionally on an excel spreadsheet once the information has been obtained from the PLC? Monthly data was being collected from the PLC and put on an excel spreadsheet using Omron CX-Server DDE. They wanted at the beginning of each month to move the data to the appropriate month so they can track the changes.

The following three blogs were posted on how to get data into the Microsoft Excel Spreadsheet from the programmable logic controller. (PLC)

HOW TO IMPLEMENT MODBUS TCP PROTOCOL USING VBA WITH EXCEL

IMPLEMENTING THE OMRON CX SERVER DDE AND EXCEL

HOW TO IMPLEMENT THE OMRON HOST LINK PROTOCOL PART 2 – VBA

The method to move the data around the spreadsheet once the data has been obtained will be done by Visual Basic for Applications. (VBA)

Make a spreadsheet in excel as follows:

Operation:
When the current data in A2 or B2 changes, it will trigger a macro to execute. This macro will use the Worksheet_Change to trigger the code. The date in A2 is then compared to all of the dates located from A5 to A30. If a match is found then the value in B2 is placed beside the matching date found column. Example: A2 = A7 then B7 = B2
Here is a look at the VBA editor and code:

Here is the following code:
Private Sub Worksheet_Change(ByVal Target As Range)
If Target.Address = “$A$2” Or Target.Address = “$B$2” Then
For x = 5 To 30
If Sheets(“Sheet1”).Range(“A2”) = Sheets(“Sheet1”).Range(“A” & x) Then
Sheets(“Sheet1”).Range(“B” & x) = Sheets(“Sheet1”).Range(“B2”)
End If
Next ‘x
End If
End Sub

Download the example excel file.

Watch on YouTube : Excel Conditional Movement of Data
If you have any questions or need further information please contact me.
Thank you,
Garry



If you’re like most of my readers, you’re committed to learning about technology. Numbering systems used in PLC’s are not difficult to learn and understand. We will walk through the numbering systems used in PLCs. This includes Bits, Decimal, Hexadecimal, ASCII and Floating Point.

To get this free article, subscribe to my free email newsletter.


Use the information to inform other people how numbering systems work. Sign up now.

The ‘Robust Data Logging for Free’ eBook is also available as a free download. The link is included when you subscribe to ACC Automation.

Implementing the Omron CX Server DDE and Excel

Utilizing the CX Server DDE Manager will allow us to provide a link to the information in the Omron PLC. This link can be placed on an Excel spreadsheet. Charts, graphs, etc. can be made from the data. We will create links on an excel spread sheet from a CQM1H and a CP1L PLC. The information will then be displayed as a bar graph comparing the first ten memory areas.

Dynamic Data Exchange (DDE) is a channel through which correctly prepared programs can actively exchange data and control other applications within Microsoft Windows. The DDE manager will allow us to set up all of the links.

Start the DDE Manager by clicking Start/Programs/Omron/CX-Server/DDE Manager

This will start the DDE Manager and place an icon on your toolbar at the bottom of your screen. The application will run minimized.

Right-click on the minimized DDE Manager icon and select Project/New.

Assign a filename (ACC DDE.cdm) to the CX-Server project that you will create, and save it.

The create project will minimize to the taskbar. Right-click on the minimized DDE Manager icon and select Project/Edit.

This will call up the DDE Manager Project Editor. We can now add the PLC’s (Devices) and Points that we want to display.

Select File/New/PLC, or hit the PLC Icon on the taskbar.

Under Change PLC, we can now enter the information about how we are communicating to the programmable logic controller.

Device Name: – Name in which the DDE Manager will call the PLC
Device Type: – The model of PLC that will be connected
Network Type: – This is the communication method that we will be talking with the device.

In our example we will use the following two Omron PLCs.

  • CQM1H – SYSMAC WAY (Omron Host Link Protocol) Communication Port  11, 9600, E, 7, 2. Unit #00
  • CP1L – USB

 Once we have the PLC information, we can now add points that will contain the information that we wish to retrieve from the units. Select File/New/Point  or select the point editor icon to start the point editor.

On the Logical tab you can give a name (Or Change) to the point in the PLC to get. Select the Physical tab.

On the physical tab we set the following information:
PLC: – This is the list of PLCs entered in the previous step
Data Location: – The memory location that we want to read from
Internal Data Type: – This is the interpretation of the data that we are reading. (Example: Bit, Word, BCD, etc.)
Command Modifier: – This is used if we need to Force Set / Reset the data location. This can be used to override the PLC program. Use with caution.
Press OK when finished setting the address.

 Our point is now programmed. You will notice the symbols before the name of the point. This tells us at a quick glance what type of data we are looking at. Please refer to the CX Server Runtime manual for all of the symbol meanings.

Fill out the remaining points for our example.
CP1L – D0 to D9
CQM1H – DM0 to DM9

Start Microsoft Excel.

Go back to the DDE manager and the points under the Project Editor. We can now select the first ten items in the list. Click the first one and then move to the last item. Hold the shift while clicking the last item will select all of them between.
Hit the DDE Link icon.

In Excel, we now paste the information onto the worksheet. (Ctrl + V) Right click the cell and select paste.

The information will now be displayed and updated  on your worksheet.
The update time will depend on the interval set in the DDE Manager. Right-click on the minimized DDE Manager icon and select Update Interval…

We can also set individual point update times in the DDE link item. The default update time is set via the DDE Manager but we can also set the time in the individual points on the spreadsheet.
DDE Update Default Link:
=CDMDDE|’C:\ACC DDE.cdm’!’\CP1L D0′
5 Second Update Link:
=CDMDDE|’C:\ACC DDE.cdm’!’\CP1L D0,5′

In the Project Editor of the DDE Manager you can see the first 10 memory areas are being used. This is the yellow triangle with the lightning bolt symbol. (You will not be able to delete the point if it is in use.)

Calling up an excel file with the links embedded, will give you a Security Alert – Links warning. Select ‘Enable the content’ and then hit OK.

Here is an example of the finished excel file. We have 10 memory locations from each PLC listed. We have inserted a graph that will dynamically change when the values are read.
Download the excel file here.

 As you can see implementing the CX Server DDE Manager is not a difficult task. It provide a quick and efficient way to view the information that we need.

Additional Information:
Excel – Conditional Movement of Data

Watch on YouTube : Implementing the Omron CX Server DDE and Excel
If you have any questions or need further information please contact me.
Thank you,
Garry



If you’re like most of my readers, you’re committed to learning about technology. Numbering systems used in PLC’s are not difficult to learn and understand. We will walk through the numbering systems used in PLCs. This includes Bits, Decimal, Hexadecimal, ASCII and Floating Point.

To get this free article, subscribe to my free email newsletter.


Use the information to inform other people how numbering systems work. Sign up now.

The ‘Robust Data Logging for Free’ eBook is also available as a free download. The link is included when you subscribe to ACC Automation.

How to Implement the Omron Host Link Protocol Part 2 – VBA

ACC Omron Host Link VBA

In Part 1, we used VB6 to communicate from the computer to the PLC. We will now use Visual Basic for Applications (VBA) to accomplish the same task. NETComm will be the serial driver and Excel will be the program that we will use. Using Excel we will have access to the Excel Object Model so we can utilize worksheets, ranges etc.

Please refer to Part 1 (How to Implement the Omron PLC Host Link Protocol) for the details of the wiring of the serial port and protocol sequence.

The first step in using VBA is to download and register NETComm.ocx. To use serial communications with VBA you must register the NETComm.ocx driver.

Download the NETComm.ocx file to the c:\ directory.

Call up a dos prompt with administrator authority. (Right click on the cmd.exe program and select run as administrator.)

Type ‘regsvr32 netcomm.ocx’

An information box will be shown indicating that the NETComm.ocx was registered successfully.

Now open Excel and make the following on Sheet 1.

Select Developer and then Visual Basic.

If you do not have the Developer option to select, then do the following:
Select File : Options: Customized Ribbon
Select Developer and hit OK

VBA – Visual Basic for Applications will open

Insert a user form.

Add NETComm1 to UserForm1. If it is not on your Toolbar, then select additional controls and select NETCommOCX.NETComm. Press the OK. Then drag this control onto your form.

Create three command buttons. This can be done by going to Design Mode,  and under the Insert menu you can select Command Buttons.

Here is the entire code for the application:

Private T$ ' Modual Scope for variable
Private TRead$
Private NumWords
Private startcycle
Private Sub CommandButton1_Click()
If NumWords = "" Then
    MsgBox "Set Read String"
    Exit Sub
End If
If startcycle = 0 Then
    startcycle = 1
    CommandButton1.BackColor = "&H0000FF00"
Else
    startcycle = 0
    CommandButton1.BackColor = "&H8000000F"
    UserForm1.NETComm1.PortOpen = False ' Close Communication Port
    Exit Sub
End If
UserForm1.NETComm1.PortOpen = True ' Open Communication Port
Application.EnableEvents = True
Do
    T$ = TRead$ ' Reset the Transmitted Information
    charreturn = 11 + (NumWords * 4) ' Determine the return characters
    GoSub FCS ' Checksum
    GoSub communicate ' Get informaiton
    
    'Check returned information and Display
    If Mid(rxd$, 6, 2) = "00" And (Len(rxd$)) >= charreturn Then
        For x = 1 To Sheets("Sheet1").Range("D7")
            Sheets("Sheet1").Range("B" & x + 10 - 1) = Mid(rxd$, x * 4 + 4, 4)
        Next 'x
    End If
    DoEvents ' Do other tasks
    'Update the date and time
    Sheets("Sheet1").Range("C09") = Format(Date, "YYYY/MM/DD") + "    " + Format(Time, "HH:MM:SS")
Loop While startcycle = 1
If startcycle = 0 Then Exit Sub
communicate:
rxd$ = ""
Buffer = T$ + FCS$ + "*" + Chr$(13)
UserForm1.NETComm1.Output = Buffer
Time1 = Now
Timeout = Now + TimeValue("0:00:02")
Do
    If Timeout <= Time1 Then GoTo timeoutcom
    DoEvents
    Time1 = Now()
Loop Until UserForm1.NETComm1.InBufferCount >= charreturn
rxd$ = UserForm1.NETComm1.InputData
fcs_rxd$ = Left((Right(rxd$, 4)), 2)
If Left(rxd$, 1) = "@" Then
    T$ = Mid(rxd$, 1, (Len(rxd$) - 4))
ElseIf Mid(rxd$, 2, 1) = "@" Then
    T$ = Mid(rxd$, 2, (Len(rxd$) - 5))
    rxd$ = Mid(rxd$, 2, (Len(rxd$) - 1))
End If
GoSub FCS
If FCS <> fcs_rxd$ Then
    rxd$ = ""
End If
clearbuffer$ = UserForm1.NETComm1.InputData
Return
FCS:
    L = Len(T$)
    A = 0
    For J = 1 To L
        TJ$ = Mid$(T$, J, 1)
        A = Asc(TJ$) Xor A
    Next J
    FCS$ = Hex$(A)
    If Len(FCS$) = 1 Then FCS$ = "0" + FCS$
Return
timeoutcom:
If startcycle = 0 Then Exit Sub
clearbuffer$ = UserForm1.NETComm1.InputData
rxd$ = ""
Return
End Sub
Private Sub CommandButton2_Click()
If startcycle = 0 Then
    UserForm1.NETComm1.CommPort = Sheets("Sheet1").Range("A4")
    UserForm1.NETComm1.Settings = Sheets("Sheet1").Range("B4") & "," & Sheets("Sheet1").Range("C4") & "," & Sheets("Sheet1").Range("D4") & "," & Sheets("Sheet1").Range("E4")
    MsgBox UserForm1.NETComm1.Settings
Else
    MsgBox "Stop Reading Parameters to Set MSComm"
End If
End Sub
Private Sub CommandButton3_Click()
If startcycle = 0 Then
    Unit = Sheets("Sheet1").Range("A7")
    If Len(Unit) < 2 Then Unit = "0" & Unit
    StartADD = Sheets("Sheet1").Range("C7")
    Do
        If Len(StartADD) < 4 Then
            StartADD = "0" & StartADD
        End If
    Loop Until Len(StartADD) = 4
    NumWords = Sheets("Sheet1").Range("D7")
    Do
        If Len(NumWords) < 4 Then
            NumWords = "0" & NumWords
        End If
    Loop Until Len(NumWords) = 4
    T$ = "@" & Unit & "RD" & StartADD & NumWords
    TRead$ = T$
    MsgBox T$
    For x = 1 To Sheets("Sheet1").Range("D7")
        Sheets("Sheet1").Range("A" & x + 10 - 1) = "DM " & Sheets("Sheet1").Range("C7") + x - 1
        Sheets("Sheet1").Range("B" & x + 10 - 1) = ""
    Next 'x
    For x = Sheets("Sheet1").Range("D7") To 200
        Sheets("Sheet1").Range("A" & x + 10) = ""
        Sheets("Sheet1").Range("B" & x + 10) = ""
    Next 'x
Else
    MsgBox "Stop Reading Parameters to Set Read String"
End If
End Sub
Private Sub Worksheet_SelectionChange(ByVal Target As Range)
End Sub

Note: The Chart on Sheet1 is just a selection of the first ten DM areas and insert a bar graph.

Running the program produces the following information:
 

Download the excel file ACC Omron Host Link VBA.XLS. This is the complete program mentioned above.

 

When you open the file it will warn you about macros. This is the VBA application. Press ‘Enable Macros’.

When changing the parameters on the screen, you will also get a warning about Active X. This is the NETComm.ocx which was registered above. Press ‘OK’ to run the application.

Additional Information:
Excel – Conditional Movement of Data

Watch on YouTube : How to Implement the Omron Host Link Protocol Part 2 – VBA
If you have any questions or need further information please contact me.
Thank you,
Garry



If you’re like most of my readers, you’re committed to learning about technology. Numbering systems used in PLC’s are not difficult to learn and understand. We will walk through the numbering systems used in PLCs. This includes Bits, Decimal, Hexadecimal, ASCII and Floating Point.

To get this free article, subscribe to my free email newsletter.


Use the information to inform other people how numbering systems work. Sign up now.

The ‘Robust Data Logging for Free’ eBook is also available as a free download. The link is included when you subscribe to ACC Automation.

Now You Can Have Data Logging Free

A data logger is also known as a data recorder or  data acquisition. It is a method to record data over a period of time and/or events.

The recorded information can come from sensors in the field. They can be digital or analog. With analog (voltage or current) we can measure temperature, pressure, sound, weight, length, etc. Digital data can be used for counts, times, events (motor overload), etc.

Data collecting can be time or event driven. Time based would be like collecting data every minute, shift, day etc. An event based collection would be from an error in the field such as an overload of a motor or a fault with a temperature controller.

Data mining / analysis is the most important part of the data logging.

Data mining / analysis is the way in which we look at the data and determine  what to do. Clustering is a method to look at the data in similar groups for comparison. An example of this would be the amount of material made on individual shifts in the plant.  Setting up the data logging in a way to examine the output over time is very helpful in determining methods to increase productivity in the manufacturing environment.

Time studies or observations are vital in the lean manufacturing world. Data logging can be useful in assisting with these studies. However, unlike the usual manual approach, this time study can be continuous.

Doing Time Observations

Data logging does not have to be expensive. It is also not as intimidating as it may sound.

The ‘Robust Data Logging for Free’ eBook is available in a free download. Just subscribe to ACC Automation to get the link for the free download.
 
This eBook will walk you though step by step on getting information into a database so you can start analysing the data. With traditional loggers, software will read the memory of the PLC and store in a local computer. If the network stops or the PLC communication fails then the logging will stop.
Creating a robust PLC data logger allows the communication to be stopped for a period of time without losing any of the data for collection. This is accomplished by storing the data locally on the PLC until communication is restored. All of the data is then read without loss. The amount of time that the connection can be lost will be dependent on the memory size of the PLC and the frequency of the data collected.
This series will walk you through the steps to create and implement a robust PLC data logger using the following equipment and hardware.
  • Automation Direct – Do-More – H2-DM1E PLC (Ethernet Modbus TCP)
  • Do-more Designer 1.3 (Simulator instead of PLC mentioned above)
  • Windows based computer running IIS
  • Visual Basic 6

Additional information on Omron Host Link Protocol and Indirect Addressing can be found in the eBook.

The ‘Robust Data Logging for Free’ eBook is available for a free download. Just subscribe to ACC Automation on the left side menu of the website to get the link for the free download.

Watch on YouTube : Now You Can Have Robust Data Logging For Free
If you have any questions or need further information please contact me.
Thank you,
Garry



If you’re like most of my readers, you’re committed to learning about technology. Numbering systems used in PLC’s are not difficult to learn and understand. We will walk through the numbering systems used in PLCs. This includes Bits, Decimal, Hexadecimal, ASCII and Floating Point.

To get this free article, subscribe to my free email newsletter.


Use the information to inform other people how numbering systems work. Sign up now.

The ‘Robust Data Logging for Free’ eBook is also available as a free download. The link is included when you subscribe to ACC Automation.

How to Implement the Omron PLC Host Link Protocol

Hostlink communication protocol is a method developed by Omron for communication to PLC’s and other equipment. This ASCII based protocol is used over RS232 or RS422/RS485. It is a many to one implementation which means that you can communicate with up to 32 devices back to a master. (1:N) This communication on the industrial floor can control PLC’s, Temperature Controllers, Panel Meters, etc.

Our look at this protocol will include the wiring, setting of RS232 port settings, protocol format and  writing a VB6 program to read information from the PLC. I will also point you links to then store this information into a database and share over an intranet/internet. Lets get started.

Wiring of the communication ports will depend on the equipment purchased. If communicating over 15 meters, it is recommended to switch to RS422 or RS485 connection. However I have seen RS232 runs of 50 meters without an issue. It will depend on your implementation and electrical noise in the plant.

The above diagram is the basic communication needed for RS232C. Note that the shield of the communication wire is connected only to one side. This ensures that any noise induced in the communication is filtered to one end.

Settings for RS232C communications are set in a number of ways. Older Omron C**K PLC were set through a series of dip switches. Current Omron SMR1/CPM1 PLC’s are set though data memory locations.
Note: Most of the time, you need to cycle the power or switch to program / run mode for the setting to be activated.

I generally tend to leave everything at the default settings: 9600 bps, Even parity, 7 data bits, 1 stop bit. The default host link unit number is 00. (32 max. – 00 – 31)

Protocol Format
Each piece of equipment will have a list of parameters that can be read and written using the HostLink protocol. This can be found in the programming manual of the device. Here are the areas in the CPM1/CPM1A/CPM2A/CPM2C/SRM1(-V2) from the programming manual.

Lets take a look at the command to read the DM area. All of the commands and responses will be in an ASCII format.

The command format begins with a ‘@‘ sign followed by the Node / Unit number that you wish to communicate. Header code is the command in which you with to execute. (RD) This header code will determine the next series of information. In our case the next four digits will be the beginning word followed by the next four digits to indicate the number of words. The next part of the command is the FCS (checksum) calculation. The comparison to this at each end will ensure that the command/response is correct. FCS is a 8 bit data converted into two ASCII characters. The 8 bits are a result of an Exclusive OR performed on the data from the beginning to the end of the text in the frame. In our case this would be performed on the following:

"@00RD00000010"

The last part of the command is the terminator. This is an ‘*’ followed by the character for the carriage return. (CHR$(13))

The response format begins with a ‘@’ sign followed by the Node / Unit number that you are communicating to. The header code is next (RD) followed by the End Code. The end code is a two digit ASCII code that indicates the message response / errors when executing the action. A normal code of ’00’ indicates that everything is fine. See the operation manual for the entire list of end codes for your equipment. The next part of the response depends on the header code executed. In our case it would contain the data requested. The last two parts of the response is the FCS and terminator just like the command format.

The above shows the timing of the command and responses.

Visual Basic VB6 (Example)
Now lets look at an example of reading the first 10 words from the DM area  of an Omron PLC.

The first step is the design the form. You can see that we have our ten DM area words set out to populate with values. We also have a T$ for transmit. This will show what we are sending to the PLC. The RXD$ will show what the response will be from the PLC.

The MSComm is used to communicate through the serial ports of the computer. The following is the settings for the communication port.

Here is the VB6 code for the program:
When the form loads the Date/Time will get updated and Timer1 is enabled. This timer controls the interval in which the commands get executed. (Set to 1 second)

Private Sub Form_Load()
 Label2.Caption = Format(Date, "YYYY/MM/DD") + "    " + Format(Time, "HH:MM:SS")
 Timer1.Enabled = True
 End Sub

The following code will open the communication port, set the command format, send the command through the port, receive the response through the port and display the information. It will then close the communication port.

Private Sub Timer1_Timer()
 Timer1.Enabled = False
 MSComm1.PortOpen = True
 Label2.Caption = Format(Date, "YYYY/MM/DD") + "    " + Format(Time, "HH:MM:SS")
'Check DM AREA DM0000 to DM0009 data update
 T$ = "@00RD00000010"
 charreturn = 51
 GoSub FCS
 GoSub communicate
'Show Transmit information
 Label24.Caption = Buffer
 'Show Returned information
 Label26.Caption = rxd$
If Mid(rxd$, 6, 2) = "00" And (Len(rxd$)) >= charreturn Then
 Label4.Caption = Mid(rxd$, 8, 4)
 Label6.Caption = Mid(rxd$, 12, 4)
 Label8.Caption = Mid(rxd$, 16, 4)
 Label10.Caption = Mid(rxd$, 20, 4)
 Label12.Caption = Mid(rxd$, 24, 4)
 Label14.Caption = Mid(rxd$, 28, 4)
 Label16.Caption = Mid(rxd$, 32, 4)
 Label18.Caption = Mid(rxd$, 36, 4)
 Label20.Caption = Mid(rxd$, 40, 4)
 Label22.Caption = Mid(rxd$, 44, 4)
 End If
 Timer1.Enabled = True
 MSComm1.PortOpen = False
 Exit Sub

The following is the subroutine to communicate. Timer2 is the amount of time to wait before expecting an answer on the communication port. Once the command has been sent a maximum of two seconds is waited for an response. If no response nothing is returned. When the response is obtained, the FCS is checked and if correct the information is returned.

communicate:
 rxd$ = ""
 Buffer = T$ + FCS$ + "*" + Chr$(13)
 MSComm1.Output = Buffer
 Timer2.Enabled = True
 Do
 DoEvents
 Loop Until Timer2.Enabled = False
 If Time > #11:59:50 PM# Then
 timeout = #12:00:02 AM#
 Else
 timeout = DateAdd("s", 2, Time)
 End If
 MSComm1.InputLen = 0
 Do
 If timeout <= Time Then GoTo timeoutcom
 DoEvents
 Loop Until MSComm1.InBufferCount >= charreturn
 rxd$ = MSComm1.Input
 fcs_rxd$ = Left((Right(rxd$, 4)), 2)
 If Left(rxd$, 1) = "@" Then
 T$ = Mid(rxd$, 1, (Len(rxd$) - 4))
 ElseIf Mid(rxd$, 2, 1) = "@" Then
 T$ = Mid(rxd$, 2, (Len(rxd$) - 5))
 rxd$ = Mid(rxd$, 2, (Len(rxd$) - 1))
 End If
 GoSub FCS
 If FCS <> fcs_rxd$ Then
 rxd$ = ""
 End If
 clearbuffer$ = MSComm1.Input
 Return

This is the FCS (checksum) calculation routine.

FCS:
 L = Len(T$)
 A = 0
 For J = 1 To L
 TJ$ = Mid$(T$, J, 1)
 A = Asc(TJ$) Xor A
 Next J
 FCS$ = Hex$(A)
 If Len(FCS$) = 1 Then FCS$ = "0" + FCS$
 Return

This is the routine that will execute if the response is not received within the time period expected.

timeoutcom:
 clearbuffer$ = MSComm1.Input
 rxd$ = ""
 Return
End Sub

Timer2 was used as a delay before looking for a response after sending the command.

Private Sub Timer2_Timer()
 Timer2.Enabled = False
 End Sub

Here is the code running:

Helpful Tips/Links:
– When troubleshooting serial communications it is sometimes helpful to use HyperTerminal. This program will send and receive information in/out of the serial ports.
HostLink Command Generator
HostLink Command Format

Watch on YouTube : How to Implement the Omron PLC Host Link Protocol

If you have any questions, need further information or would like a copy of this program please contact me.
Thank you,
Garry