The share link has been copied to clipboard
Home Improvement
Manufacturing
Networking

Stride Field Ethernet Remote IO Modules Powering and Configuring

338 views · Oct 13, 2022
Visit Channel:publisher-humix
The Stride Field Ethernet Remote I/O Modules are simple and compact. They provide an economical means to connect inputs and outputs to an Ethernet Modbus TCP communication network. Every module operates as a standalone Modbus TCP server and can be configured via a built-in web server. We will be looking at the following two Stride Remote IO Modules: SIO-MB12CDR - STRIDE discrete combo module, Input: 8-point, 12-24 VDC, sinking, Output: 4-point, relay, (4) Form C (SPDT) relays, 2A/point, (1) Ethernet (RJ45) port(s), Modbus TCP server. SIO-MB04ADS - STRIDE analog input module, 4-channel, current/voltage, 16-bit, isolated, input current signal range(s) of +/- 20 mA, input voltage signal range(s) of +/- 10 VDC, (1) Ethernet (RJ45) port(s), Modbus TCP server, external 20-30 VDC required. We will be unboxing both of these units. Powering and then setting them up (configuring) via the webserver. Let’s get started. More information can be obtained on our website. This includes all of the links mentioned in this video. https://accautomation.ca/stride-field-remote-io-modules-modbus-tcp-ethernet Stride Field Remote IO Modules Unboxing SIO MB12CDR and SIO MB04ADS https://youtu.be/GbZNgcbVaLM Stride Field Remote IO Modules Powering and Configuring https://youtu.be/oVzWgkUn-D0 There are several reasons why we are using the Stride Field IO. Here are just a few. • Interfaces remote I/O points to a Modbus TCP network via Ethernet 10/100 Base-T • Analog current, voltage, resistance & temperature inputs available • Digital inputs available • Analog current and voltage outputs available • Discrete relay and transistor outputs available • Isolated power sources • Integrated web server for status and configuration • Remotely configurable • Removable screw terminals • LED status signaling • Galvanic isolation • IP20 rated • –10°C to +40°C UL operating temp. (–10°C to +60°C non-UL) • UL listed / CE mark • DIN rail mounting The Stride Field Remote IO Modules Modbus TCP Ethernet has all of these features. This gives you the flexibility to expand your system based on your application. https://www.accautomation.ca
Show More

Comments

loading text loading
loading text loading
loading text
loading text loading
loading text
loading text loading
loading text
loading text loading
loading text