0:01
creating a node red flow program in the
0:03
click plus PLC c2n red
0:06
module node red is an Innovative and
0:09
Powerful tool for connecting Hardware
0:11
devices apis and online services
0:14
regarding Industrial Automation The
0:16
Click plus PLC C2 node red module takes
0:19
things up a notch by integrating node
0:21
red allowing users to create flows via a
0:25
interface previously we updated the
0:27
click programming software to version 3
0:30
.70 firmware in the click PLC CPU and
0:34
c2n red module were then updated to the
0:37
latest versions We will guide you
0:39
through creating your first node red
0:41
flow program in the click plus PLC C2
0:44
and red module we will read and write
0:47
information to and from the click PLC
0:49
CPU we will discuss saving and
0:52
retrieving our flow programs and
0:53
troubleshooting let's get started
0:56
detailed information contained in this
0:57
video can be found at ACC automation. CA
1:00
a link has been put in the description
1:01
below if you have not watched the other
1:03
videos yet there are links in the
1:04
description below that will start you a
1:06
video One there'll be links to the rest
1:07
of the videos in the series as
1:15
red when first applying power to the
1:17
click system with the c2n red module it
1:20
will take up to 45 seconds for the
1:22
module to be booted here's the meanings
1:24
of the lights on the C2 and red card in
1:28
our post click plus c P2 n red easy
1:31
install for PLC module we updated the
1:33
firmware in our click plus CPU to
1:35
version 3.70 and updated the firmware on
1:38
our intelligent module C2 and red we
1:41
then set up the CPU and C2 and red to
1:48
Network to start and program our node
1:51
red module select open node red from the
1:54
PLC tab of the main menu in the click
1:58
software select the ethernet option and
2:00
select connect your default browser will
2:03
open up and you will see the node red
2:05
programming screen for the c2n red
2:07
module another way to start the old red
2:10
interface is to start a new tab in the
2:12
browser and paste the URL address and
2:15
port for the programming set copy in the
2:17
C2 and red configuration screen in the
2:20
click DLC programming
2:24
software what is flow
2:27
programming node red may feel un
2:29
familiar to those with experience with
2:31
latter Logic the graphical programming
2:33
language GPL or scripting languages on
2:37
the other hand individuals accustomed to
2:39
scripting languages like JavaScript they
2:40
find lateral logic in a click plus PLC
2:43
quite puzzling each of these three
2:45
languages has its strengths but
2:47
combining them in the click plus C2 and
2:50
red module opens up Innovative
2:52
approaches to Industrial control and
2:54
maker space commercial
2:55
applications node red introduces a third
2:58
type of programming called flow editor
3:01
similar to latter logic this editor is a
3:04
GPL graphic programming language and
3:06
operates like a flowchart where each
3:08
node represents a specific function
3:11
these functions can range from simple
3:12
tasks such as checking a data value to
3:14
more complex operations like calling a
3:16
web server to retrieving a block of
3:18
information behind the scenes node red
3:21
builds a JavaScript application and can
3:23
even incorporate function blocks that
3:25
are JavaScript sub routines
3:30
understanding the node red
3:33
interface the node red interface
3:35
consists of several panels pallet you
3:39
can find nodes to drag onto your
3:51
left workspace the central area where
4:08
info panel information about selected
4:11
nose is provided on the
4:20
right help file this area will show you
4:23
two areas the node red help will show
4:26
you changes in the software version and
4:28
you can display the tour as as we did
4:30
before node help you will have all the
4:33
help files for the nodes installed on
4:50
pallet debug panel this area lets you
4:54
view outputs and log messages to help
4:57
debug your flow troubleshooting your
4:59
code becomes easy with a debug
5:01
panel config panel this will help
5:04
configure your flows or specific nodes
5:09
system building your firstclick read
5:14
flow let's create a simple flow that
5:16
reads inputs from our click plus
5:19
PLC all the pallet NOS can be dragged
5:22
and dropped onto the workspace start by
5:24
dragging an inject mode from the pallet
5:27
to the workplace this node will serve as
5:30
now drag and drop click read and debug
5:34
workspace the red triangle means that
5:36
there is something not right with a
5:37
setup of this node double click and set
5:39
the address to read our input switches
5:41
on our click plus PLC this is address
5:44
2011 bits 1 to 8 so the size is
5:48
eight you will see that these settings
5:50
are initially in Red so the red triangle
5:53
was shown the memory type can be
5:56
selected for all different click PLC
6:00
the name that appears on the workspace
6:02
for the node can be changed but we will
6:03
leave this as the default under the
6:06
option tab select show error text show
6:09
error code this will Aid Us in
6:11
troubleshooting our code select done
6:15
none of the nodes now have an error join
6:17
the nodes together by clicking the
6:18
outputs to the inputs start with the
6:20
inject Noe joining to The Click read
6:23
node then the click read node is linked
6:26
to the debug node once everything is
6:28
connected and configured click the
6:30
deploy button this action saves and runs
6:33
your flow a message successful deployed
6:37
shown select the debug tab on the right
6:40
hand side this will show us the message
6:42
sent from The Click read in the
6:45
debug click on the button in the inject
6:48
node to trigger or flow you should see
6:51
the output in the debug panel this is a
6:53
message object payload expanding the
6:55
message payload you will know we have a
6:57
result data and result text this is all
7:01
the information being sent from The
7:02
Click read node expand the data you'll
7:06
find an array representing all the
7:09
requested change the switch State on the
7:12
PLC and Trigger the flow again you will
7:15
now see the updated switch
7:26
conditions selecting the delete all in a
7:29
debug window will clear the debug window
7:31
notice that you will also see the
7:33
success indication Under The Click read
7:35
node this gives us a quick visual that
7:38
indicates their flow is
7:40
working if you're enjoying this video
7:42
please hit the like button keeping up
7:44
with all the latest automation
7:45
Innovations can be difficult so hit the
7:47
Subscribe button remember to click the
7:49
Bell beside your subscription to
7:50
actually receive those
7:54
notifications adding a click right to
8:00
dragging a click right node from the
8:01
pallet to our workspace join the click
8:04
read output to The Click right input the
8:07
red triangle on the click right means we
8:09
need additional information for this
8:11
node double click it we will set the
8:13
address to 101 and a size to eight this
8:17
represents the first eight outputs on
8:22
PLC the memory type will show you the
8:24
different areas we can write to in the
8:31
under the option tab select show error
8:34
text show error code select
8:38
done drag and drop another debug node
8:50
right click the deploy
8:53
button select the injection node for our
8:56
flow we have an error this is despite
8:59
Under The Click right node as well as
9:01
for the debug to the eror is that the
9:04
input payload is not an
9:07
array this is because our output from
9:09
The Click read is more than just an
9:11
array it also contains the result and
9:13
result text we can separate this
9:15
information coming from The Click read
9:17
node by using a function node drag and
9:20
drop a function node onto the
9:22
workspace looking at the debug message
9:24
after the click read you can find the
9:27
path to the data array
9:30
click on the copy path for the
9:32
data double click on the function node
9:36
the on message tab will be displayed we
9:38
can write JavaScript within the function
9:41
node paste our copy path for the data
9:44
array from our click read
9:47
node our JavaScript line will read
9:50
message. payload equals message. payload
9:55
semicolon the semicolon at the end of
9:57
the line is necessary for JavaScript
9:59
programming the function node also has
10:02
tabs for setup on start on
10:06
Stop The Help menu will help you with
10:13
done join the function node output to
10:16
The Click right input select delete the
10:19
debug 2 node connection and join it with
10:21
the output from the function node add
10:24
another debug node to the output of the
10:26
click right instruction
10:36
deploy the flow ensure the debug area
10:39
window is clear and press the inject
10:45
mode our flow is now working this is
10:48
easily seen by the success under each
10:50
click read and write
10:52
node in a debug window we can see our
10:55
output from debug 2 is now just an array
10:57
of values which then is written into the
11:02
PLC changing the switch inputs on the
11:05
PLC and clicking the inject mode will
11:10
outputs debug nodes can be turned on and
11:13
off by selecting the output on the Node
11:15
turn off debug one and three from the
11:17
read and write nodes deploy and inject
11:20
the flow we will only see the array red
11:23
and written to our click plus plc
11:40
configure the inject
11:43
node double click the inject node to
11:46
configure it we will leave the payload
11:48
type as a default type
11:51
timestamp we will set the inject time at
11:53
regular intervals this will be the
11:55
frequency of when our flow will function
12:01
select done and deploy our click PLC
12:05
inputs are being read and written every
12:08
seconds change the input switches to
12:11
reflect in the click PLC
12:13
outputs remember that we only have an
12:15
end statement in our latter logic code
12:18
node red is doing all the
12:22
control saving the no red flow export
12:29
click the pancake symbol beside the
12:31
deploy button we can now select export
12:33
contrl plus e the export nodes window
12:36
will be displayed we can choose select
12:38
current or all Flows at the windows top
12:42
select current flow and then select
12:46
download this will download a Json file
12:49
of your flow you can rename this file
12:53
program select the export again from the
13:00
after selecting the nodes for flows that
13:02
we want to save click copy the clipboard
13:05
we can now open any text editing
13:07
software like Windows notepad and paste
13:09
the Json information copied to the
13:37
the import control plusi is used to take
13:39
the Json file and restore your flow or
13:42
flows that have been
13:46
congratulations you've successfully
13:47
created your first node red flow program
13:50
within the click plus CPU C2 and red
13:53
module to learn more about programming
13:55
with node red click here click here to
13:57
learn more about the click plus PLC this
14:00
is just the beginning you can expand
14:02
your flows by adding more nodes
14:04
connecting to different devices or
14:05
integrating with apis with practice
14:08
you'll unlock the vast potential that
14:09
node red offers for Industrial
14:11