Click PLC Start Stop One Input

792 views Nov 17, 2022

Click PLC Start Stop One Input This circuit is the safest way to start and stop a physical output using just one input. You can use a standard flip-flop circuit if this is internal and not a physical output. Links are provided in the description below. An on-delay timer will start the output. The operator will press and hold the input to start (turn on) the output. The leading edge of the input signal is detected, and an internal bit is set for one PLC scan. This will stop the output. The timer done bit will start the output, and the output will seal in the timer done a bit, making the output stay on. The normally closed one-shot internal bit will stop the output. PLC Ladder Logic Flip Flop Circuit https://accautomation.ca/creating-a-flip-flop-circuit-in-the-plc/ Download this Click PLC Sample program: https://www.dropbox.com/s/03or90n2bzjqn0v/Click%20PLC%20How%20to%20Connect%20Pushbutton%20Switch%20to%20Programmable%20Controller.zip?dl=0 Programming and examples of the Click and Click PLUS PLC series can be found at this URL: https://accautomation.ca/series/click-plc/ General information on the Click series of controllers: www.clickplcs.com/config