BRX Do-More PLC INC DEC 512 Registers for DMX512

497 views Oct 13, 2022

We will now look at inc and dec 512 registers using the BRX Do-More PLC. This is to control DMX512 fixtures. I was recently asked the following question after posting the Analog Dust to Dawn program: " I was wondering if there's an easy way to increment and decrement a range of values. e.g. I have a range of registers (V100 ~V611) the values in each register are different. But I want to increment or decrement all the registers values by 1 at the same time. So that the ramp rate is the same. Is that possible without having to do 6 rungs of logic for each register? To elaborate a little on my use case. 512 registers were chosen because that equals one DMX universe. So my scaling factor is 0~255. 16 channels are mapped to two BX-08DA-2B modules to control 0-10 fixtures. All other channels are mapped to SERIO module to control DMX512 fixtures and other devices." We will be looking at the DMX512 protocol and how to control 512 registers at a time using our BRX PLC (Do-More). Let’s get started! More information can be obtained on our website. This includes all of the links mentioned in this video. https://accautomation.ca/brx-plc-inc-dec-512-registers-for-dmx512 The entire BRX Series PLC can be found at the following location: https://accautomation.ca/series/brx-do-more-plc/ Here are the individual posts with video links: Installing the Software https://accautomation.ca/brx-plc-installing-the-software https://youtu.be/iFI1ebP8Zkk Establishing Communication https://accautomation.ca/brx-plc-establishing-communication https://youtu.be/shU5g8MA8VM

#Business & Productivity Software
  # Factory Automation