Tag Archives: plc programming examples and solutions

Stride Field Remote IO Modbus TCP Ethernet




The Stride Field Remote I/O Modules are simple and compact. They provide an economical means to connect inputs and outputs to an Ethernet Modbus TCP communication network. Every module operates as a standalone Modbus TCP server and can be configured via a built-in web server.
Stride Field Remote IO Modules Modbus TCP Ethernet
We will be looking at the following two Stride Remote IO Modules:
SIO-MB12CDR – Ethernet Modbus TCP Remote IO
Stride Field Remote IO Modules Modbus TCP Ethernet
– STRIDE discrete combo remote module, Input: 8-point, 12-24 VDC, sinking, Output: 4-point, relay, (4) Form C (SPDT) relays, 2A/point, (1) Ethernet (RJ45) port(s), Modbus TCP server.
SIO-MB04ADS – Ethernet Modbus TCP Remote IO
Stride Field Remote IO Modules Modbus TCP Ethernet
– STRIDE analog remote input module, 4-channel, current/voltage, 16-bit, isolated, input current signal range(s) of +/- 20 mA, input voltage signal range(s) of +/- 10 VDC, (1) Ethernet (RJ45) port(s), Modbus TCP server, external 20-30 VDC required.
We will be unboxing both of these units. Powering and then setting them up (configuring) via the webserver. Let’s get started. Continue Reading!

ACC Automation 2019 Review

Accelerate Learning …
Accelerate Machines…
Accelerate Knowledge…
ACC Automation

It is a good time to be in the automation business. Technologies are merging and communicating like never before. What was impossible is now possible for the industrial plant floor. We are looking forward to the New Year and new possibilities for implementing your control solution.
Each year we like to take a few minutes and reflect on the past, current, and future of ACC Automation. You have helped us to build the site that you see today through questions, comments, and suggestions. Thank you.
2019 has been our best year yet thanks to you. Keep on Reading!

Productivity 1000 Series PLC Firmware Update

Firmware is usually PLC operating system code that is written into a read-only memory. The BIOS (Basic Input Output System) of a PC (personal computer) is a good example of the firmware. It provides the low-level interface between the hardware and software. The firmware for the productivity series of PLCs must be downloaded separately from the programming software.
Productivity 1000 Series PLC Firmware Update
We will be updating our firmware of our Productivity 1000 PLC from 1.2.5.36 to the latest version 1.2.7.37. Let’s get started. Continue Reading!

ACC Automation 2018 Review

We would like to take a few minutes and reflect on the past, current and future of ACC Automation. Your questions, comments and suggestions have helped us to build the site that you see today. Thank you.
YouTube Channel : ACC Automation
2018 has been our best year yet thanks to you. Keep on Reading!

Productivity 1000 Series PLC Modbus TCP Ethernet

The productivity series of PLCs comes with 4 built-in communication ports for easy connectivity to your PC or various industrial networks. Ethernet protocols like Modbus TCP can be utilized with the RJ45 port on this PLC. Modbus TCP is an open (published) protocol that uses the Server (Master) / Client (Slave) architecture. It’s a very common protocol used in industrial automation controls.
Productivity 1000 Series PLC Modbus TCP Ethernet Communication to Click PLC
We will be using the RJ45 (Ethernet) port to communicate to a Click PLC. Modbus TCP will be the protocol used on this Ethernet communication media. The Productivity 1000 PLC will be the server and the Click PLC will be the client. We will be creating a network between the two PLC units. A heartbeat will be used so if communications is lost, the server (slave) will know. The throughput time will be timed by using a small program in the Click PLC. You will soon see how the Productivity Series of PLC’s is the best way to handle communication to other devices. Let’s get started. Continue Reading!