C-More Micro Program Quick Start

C-More Micro Program Quick Start

We will now look at the C-More Micro program quick start. This will demonstrate how to quickly get your C-More Micro Program up and communicating to your programmable logic controller. (PLC) The general steps involved with a human-machine interface (HMI) program will include, program development, ladder logic, and HMI program development. We will be breaking … Read more

C-More Drop-Down Menu Create – All Models

C-More Drop-Down Menu Create

The C-More can create a drop-down menu. This applies to all models of the HMI controller. A drop-down is a menu that offers a list of options. The currently selected item in the list is always displayed. When the visible item is selected (touched), other items from the list “drop-down” into view, and the operator … Read more

Raspberry Pi Serial Port Programming

Raspberry Pi Serial Port Programming

Node-RED will be used on the Raspberry Pi 4 to communicate serial Modbus RTU to a Solo process temperature controller and Click PLC using twisted pair RS485. This will be done on the same serial network so the devices will be daisy-chained together on the two wires. We will be reading the PV (present value) … Read more

Node-RED Modbus TCP Handling Errors

Node-RED Modbus TCP Handling Communication Errors

Node-RED Modbus TCP can recover from communication errors automatically. Options are available to you the programmer to continue the Node-RED flow upon detection of these errors. Broken Ethernet cable, Modbus Server power, and Node-RED Client offline are just a few of the errors that can occur on the industrial plant floor. Our Node-RED program must … Read more

Simple Click Data Logging – Node-RED

Simple Click Data Logging

We will now be looking at simple data logging using a Click PLC with an Ethernet port. Node-RED will be used to communicate to the controller via Modbus TCP protocol. Information collected will be then stored in an SQLite SQL database. A Raspberry Pi 4 single-board computer will be used for the Node-RED collecting and … Read more

Click Plus Real Time Clock Setup and Use

Click Plus Real Time Clock Setup and Use

The real-time clock on the Click Plus can now be more accurate. A network time service (NTP or SNTP) has been added to the Click Plus controller. This will allow the time to be synchronized with an internet time server or local network. Daylight savings time is quickly implemented with just a memory retentive bit … Read more