Category Archives: Ethernet IP Client

Don’t Get Caught Without These 3 PLC Requirements

If you are looking to purchase a PLC system, there are three key components that you should look for. If your current system does not contain these features, you need to replace it with one that does as soon as possible. The three most important features you should look for in your new PLC system are the open communications protocol, the ability to integrate easily with other methods, and the ability to have remote access. Without these three essential requirements, your PLC system will be far less effective and will be more expensive to operate than it needs to be.
Don't Get Caught Without These 3 PLC Requirements
We are all data companies that need the information for continued improvement. The industrial internet of things (IIoT) is essential, and the ability to take advantage of this starts with the hardware you specify for your PLC control. PLCs are now considered edge devices. This means that information should be able to be sent and received to the PLC controller when it is required. Keep on Reading!

Productivity 2000 Series PLC – P2000 Hardware


The Productivity 2000 series of programmable logic controllers has a slim DIN rail density form factor. This means that this micro-modular PLC can have a power supply, CPU, and seven IO modules in only 10-1/2 inches. Input and output cards can be installed, removed, or replaced without turning the power off to the PLC system. (Hot-swappable) This means that your system can remain running while troubleshooting your system hardware. The Productivity 2000 hardware supports up to 240 local I/O for discrete, analog, and motion applications with a high-performance CPU equipped with five communications ports and 29 discrete and analog I/O modules. Several remote IO options are available on this award-winning PLC in the Productivity series family.
Productivity 2000 Series PLC - P2000 Hardware Features
Productivity 1000 (Stackable Micro PLC)
Productivity 2000 (Micro Modular Programmable Controller)
Productivity 3000 (Modular Programmable Controller)
These three series by FACTS engineering currently make up the Productivity Series PLC from Automation Direct.
We will be looking at the features of the powerful P2000 controller. Let’s start by looking at the P2000 hardware. Keep on Reading!

C-More Micro Program Quick Start


We will now look at the C-More Micro program quick start. This will demonstrate how to quickly get your C-More Micro Program up and communicating to your programmable logic controller. (PLC)
C-More Micro Program Quick Start
The general steps involved with a human-machine interface (HMI) program will include, program development, ladder logic, and HMI program development. We will be breaking the HMI program development into program purpose, tag import, HMI programming, simulation, and testing.
An EA3-T4CL C-More Micro HMI will be used to communicate to a Click PLC via Ethernet. A Start/Stop circuit will be programmed with a Timer. This can be controlled via the PLC inputs or HMI inputs. The timer present value (PV) will be shown on the HMI. The set value (SV) of the timer can be changed using the HMI. Let’s get started. Continue Reading!

Productivity BRX Do-More EtherNet/IP Remote IO


We will now utilize Ethernet/IP to connect a BRX Do-More PLC as remote IO on a Productivity system. The productivity series of controllers can use explicit and implicit messaging techniques of EtherNet/IP to optimize data exchanges across the network.
Explicit messaging means that the data messages that are transmitted will contain everything needed in order to respond or decode the message. It is a normal client/server relationship with instructions explicitly spelled out in the data messages. This communication happens at times that the Client requests the information.
Implicit messaging means the data messages are streamlined. The device is configured ahead of time to know what to do with the data. This is used for time-critical messages and it functions as a typical scanner/adapter relationship. Implicit messaging is real-time. It has the ability to copy data with minimal additional information because both ends already know exactly what each bit and byte.
Productivity 1000 Series PLC BRX Do-More EthernetIP Remote IO
A BRX Do-More PLC will be set up as remote distributed inputs and outputs for our Productivity 1000 controller. Implicit Ethernet IP will be set up. The Do-More will be the Ethernet IP adapter and the Productivity will be the Ethernet IP scanner. Let’s get started. Keep on Reading!

Productivity 1000 PLC Click EtherNetIP Remote IO


We will now utilize Ethernet/IP to connect a Click PLC as remote IO on a Productivity system. The productivity series of controllers can use explicit and implicit messaging techniques of EtherNet/IP to optimize data exchanges across the network.
Explicit messaging means that the data messages that are transmitted will contain everything needed in order to respond or decode the message. It is a normal client/server relationship with instructions explicitly spelled out in the data messages. This communication happens at times that the Client requests the information.
Implicit messaging means the data messages are streamlined. The device is configured ahead of time to know what to do with the data. This is used for time-critical messages and it functions as a typical scanner/adapter relationship. Implicit messaging is real-time. It has the ability to copy data with minimal additional information because both ends already know exactly what each bit and byte.
Productivity 1000 Series PLC Click EthernetIP Remote IO
A Click PLC will be set up as remote distributed inputs and outputs for our Productivity 1000 controller. Implicit Ethernet IP will be set up. The Click will be the Ethernet IP adapter and the Productivity will be the Ethernet IP scanner. Let’s get started. Keep on Reading!