Productivity 1000 PLC Click EtherNetIP Remote IO

Productivity 1000 Series PLC Click EthernetIP Remote IO

We will now utilize Ethernet/IP to connect a Click PLC as remote IO on a Productivity system. The productivity series of controllers can use explicit and implicit messaging techniques of EtherNet/IP to optimize data exchanges across the network. Explicit messaging means that the data messages that are transmitted will contain everything needed in order to … Read more

Click PLC Real Time Clock (RTC) – Ladder Logic

The click plc has a real-time clock that will allow us to control outputs based on a date or time of day. This real-time clock (RTC) can be set from the click programming software or through the program of the controller. Our programs in the click can use the following calendar and clock values: SD19 … Read more

Productivity 1000 PLC Modbus ASCII Protocol

We will not look at the productivity 1000 plc modbus ascii protocol to the Solo process temperature controller. This will be done in ladder logic on our productivity 1000 PLC. Modbus ASCII is a communication method used for transmitting information over serial lines between electronic devices. The device requesting the information is called the Modbus … Read more

Productivity 1000 PLC to Modbus TCP RTU BX-MBIO

We will now look at the productivity 1000 plc modbus tcp rtu communication to the BX-MBIO controller. The Productivity 1000 PLC can communicate to a remote I/O (input and output) controller modules using the Modbus protocol for communications. The BX-MBIO provides both Modbus RTU and Modbus TCP interfaces. Modbus RTU is a serial communication and … Read more

Click PLC to Modbus TCP RTU Remote IO BX-MBIO

The Click PLC can communicate to a remote I/O (input and output) controller modules using the Modbus protocol for communications. The BX-MBIO provides both Modbus RTU and Modbus TCP interfaces for remote IO. Modbus RTU is a serial communication and Modbus TCP is an Ethernet communication. Modbus RTU is supported over an RS-485 serial connection. … Read more

Productivity 1000 PLC to Modbus TCP Remote IO

The Productivity Series of PLC can use Modbus TCP remote IO (inputs and outputs) from Stride. The Stride Field I/O Modules are simple and compact. They provide an economical means to connect inputs and outputs to an Ethernet Modbus TCP communication network. Every module operates as a standalone Modbus TCP server and can be configured … Read more