XY-MD02 Temp Humidity Serial UART Communication

XY-MD02 Temp Humidity Serial UART Communication

To get started with the XY-MD02 temperature and humidity sensor, we will be using the program PuTTY for serial communication. We will use RS485 serial communication to establish a connection and show how to read the values and parameters of the XY-MD02 sensor effectively. Additionally, we will explore the automatic polling feature, which allows for … Read more

XY-MD02 Sensor Setting – Modbus RTU Network

XY-MD02 Sensor Setting - Modbus RTU Network

The XY-MD02 temperature and humidity sensor uses Modbus RTU for communication. Modbus RTU (serial) works as a master (client) to slave (server) communication protocol. To add this sensor to an existing network as another unit number, you must set it up first. We will be using the Simply Modbus Master software in demo mode to … Read more

Integrating XY-MD02 Sensor Modbus RTU Click PLC

Integrating an XY-MD02 Sensor with Modbus RTU into Click PLC

Using Modbus RTU (RS485), we will connect the XY-MD02 Temperature and Humidity Sensor to the Click PLC. The Click will be the Client (Master), and the Sensor will be the Server (Slave). This is an ideal sensor to place in a panel to ensure that the panel is within a working temperature and humidity range. … Read more

Mastering PLC – What you need to know!

In the current era of automation and digitization, Programmable Logic Controllers (PLCs) have emerged as integral components for varied industries, including manufacturing, construction, and more. Mastering the PLC and what you need to know involves different facets of the PLCs. Understanding their basics to troubleshooting common concerns is crucial in optimizing their efficiency and application. … Read more

Productivity 2000 Series PLC Modbus TCP Ethernet

Productivity 2000 Series PLC Modbus TCP Ethernet

The Productivity 2000 series of PLCs has five built-in communication ports for easy connectivity to your PC or various industrial networks. Ethernet protocols like Modbus TCP can be utilized with the RJ45 port on this PLC. Modbus TCP is an open (published) protocol that uses the Server (Master) / Client (Slave) architecture. It’s a very … Read more

Arduino OPTA PLC – Ladder Diagram First Program

Arduino OPTA PLC IDE - Ladder Diagram First Program

The Arduino Opta IoT PLC allows you to conveniently program it using the Arduino PLC IDE in ladder diagram format. This is the most common industrial PLC language, a simple and intuitive method. Additionally, you can program it in any of the five official languages specified in the IEC standard and using sketches written in … Read more