BRX Do-More PLC Modbus ASCII Protocol

The Do-more PLC Modbus ASCII protocol will be used to communicate with a  Solo process temperature controller. A sample program will explain in detail how this is accomplished through a serial port. Modbus is a communication method used for transmitting information over serial lines between electronic devices. The device requesting the information is called the … Read more

Productivity 1000 PLC Modbus ASCII Serial Protocol Tutorial!

We will not look at the productivity 1000 plc modbus ascii protocol to the Solo process temperature controller. This will be done in ladder logic on our productivity 1000 PLC. Modbus ASCII is a communication method used for transmitting information over serial lines between electronic devices. The device requesting the information is called the Modbus … Read more

Productivity 1000 PLC to Modbus TCP RTU BX-MBIO

We will now look at the productivity 1000 plc modbus tcp rtu communication to the BX-MBIO controller. The Productivity 1000 PLC can communicate to a remote I/O (input and output) controller modules using the Modbus protocol for communications. The BX-MBIO provides both Modbus RTU and Modbus TCP interfaces. Modbus RTU is a serial communication and … Read more

Revolutionary PLC-BX Combo: Serial to Ethernet Breakthrough

The Click PLC can communicate to a remote I/O (input and output) controller modules using the Modbus protocol for communications. The BX-MBIO provides both Modbus RTU and Modbus TCP interfaces for remote IO. Modbus RTU is a serial communication and Modbus TCP is an Ethernet communication. Modbus RTU is supported over an RS-485 serial connection. … Read more

BRX Do-More PLC to Modbus TCP RTU Remote IO BX-MBIO

The BRX Do-More PLC can communicate to a remote I/O (input and output) controller modules using the Modbus protocol for communications. The BX-MBIO provides both Modbus RTU and Modbus TCP interfaces. Modbus RTU is a serial communication and Modbus TCP is an Ethernet communication. Modbus RTU is supported over an RS-485 serial connection. Modbus TCP … Read more

Master Industrial Automation: BX-MBIO Remote I/O Unleashed

We will be looking at the Modbus remote IO BX-MBIO-M controller. This is the Do-More Modbus Remote I/O supported protocol unit. We will discuss the hardware and then connect and configure the unit to work with our existing BRX Do-more PLC. Let’s get started. The BX-MBIO Modules are remote I/O controller modules that provide a … Read more

BRX Do-More PLC: Ultimate I/O Expansion Setup Guide

We will now look at the BRX do-more plc ethernet remote IO. The BRX Do-More PLC has its own line of remote input and output expansion units. You can add up to 8 I/O expansion units per controller (CPU) and 8 BRX expansion modules per expansion unit. This will make your system grow with your … Read more

BRX Do-More PLC to Stride Field IO Modbus TCP

We will now look at the BRX Do-More PLC Modbus TCP remote io using Stride Field io. The BRX Do-More PLC can use remote inputs and outputs from Stride. The Stride Field I/O Modules are simple and compact. They provide an economical means to connect inputs and outputs to an Ethernet Modbus TCP communication network. … Read more

Stride Field Remote IO Modbus TCP Ethernet

The Stride Field Remote I/O Modules are simple and compact. They provide an economical means to connect inputs and outputs to an Ethernet Modbus TCP communication network. Every module operates as a standalone Modbus TCP server and can be configured via a built-in web server. We will be looking at the following two Stride Remote … Read more

Click PLC Secrets: Capture 6+ Hours of Live Data History

We will now look at logging data with time and date in the Click PLC. The Click PLC can perform indirect addressing. This means that I can ask for information to be moved to and from locations in the PLC using a pointer that will indicate the address. Stephen Covey in The 7 Habits of … Read more