BRX Do-More PLC Using Modbus IO Scanner Profile

BRX Do-More PLC Using the Modbus IO Scanner Profile

The Do-More Designer Programming Software (2.9) or higher includes a Modbus I/O Scanner with some profiles for Modbus Server (Slave) devices. This will greatly reduce the time it takes to implement and troubleshoot communications in your projects. Modbus communications are done independent of the PLC scan time and will have little or no ladder logic … Read more

BRX Do-More Simple Modbus Serial Communication

BRX Do-More Simple Modbus Serial Communication

The newest Do-More Designer Programming Software (2.9) version includes a Modbus I/O Scanner. This Modbus scanner will simplify Modbus RTU serial communications to any device. Communications are done independent of the PLC scan time and will have little or no ladder logic for the program. We will be communicating to a Solo process temperature controller … Read more

BRX Do-More PLC High-Speed Input Pulse Catch

BRX Do-More PLC High-Speed Input Pulse Catch

The High-Speed Input Pulse Catch will set an output that can be seen by the PLC ladder logic scan in response to an input pulse. Inputs that are too fast to reliably be seen by the ladder logic scan time will be seen. The BRX Do-More series of programmable logic controllers have built-in high-speed inputs. … Read more

BRX Do-More PLC High-Speed Input Timer

BRX Do-More PLC High-Speed Input Timer

The High-Speed discrete inputs can be configured to measure the amount of time between pulses. When you want a scaled value representing a speed or rate, the high-speed input timer is a better option for pulse rates below 5 kHz. This is compared to using the high-speed input pulse counting selection. The BRX Do-More series … Read more

BRX Do-More PLC High-Speed Input Counter

BRX Do-More High Speed Input Counter

The BRX Do-More series of programmable logic controllers have built-in high-speed inputs. These inputs can function in Counter, Timer, or Pulse Catch modes. Every CPU will have either 6 or 10 high-speed inputs (HSI) available, depending on the model. These inputs can be used for input frequencies from 0 to 250Khz. 250Khz represents 250000 input … Read more

EasyPLC Paint Line Bit Shift – BRX Do-More PLC

EasyPLC Paint Line Bit Shift - BRX Do-More PLC

The Machine Simulator (MS) is part of the EasyPLC software suite. It has many built-in machines that are used to show different programming techniques. The paint line is one of these machines. It will use a bit shift (shift register) to track bottles along a conveyor belt. All the bottles will be detected using photocells … Read more

ACC Automation 2021 Review – Industrial Control

ACC Automation 2021 Review - Industrial Control PLC

Accelerate Learning … Accelerate Machines… Accelerate Knowledge… ACC Automation In this Covid-19 world, we are continuing to adapt. Social distancing, mask-wearing, hygiene, etc are the way we currently live. Video conferencing with Zoom, Teams, and Google Meet are the norm in business today. Information is knowledge, and everyone more than ever wants to be able … Read more

Do-More PLC – EasyPLC Box Selection Program

Do-More PLC – EasyPLC Box Selection Program

The Machine Simulator (MS) is part of the EasyPLC software suite. It has many built-in machines that can be programmed. The box selection (camera management and distribution) is one of these machines. It will read barcodes from the boxes and send them to different exit ramps. The Do-More Designer PLC Simulator will be used to … Read more

PLC Learning Series – Memory Backup

PLC Learning Series – Memory Backup

PLC memory is very similar to personal computer memory. There is the operating system and firmware of the processor and connected modules. PLC programs and data that are used by the program are also stored in the memory. We will now look at the basic understanding of memory in the PLC. Looking at two examples … Read more

Solo SL-SOFT Installation – Temperature Controller Software

Solo SL-SOFT Installation - Temperature Controller Configuration and Monitoring Software

All Solo Standard Process Temperature Controllers that support RS-485 serial communications can use the SL-SOFT configuration and monitoring software. This free package will communicate to monitor multiple SOLO controllers using Modbus RTU or Modbus ASCII protocols. We will be installing the SL-SOFT configuration and monitoring software package on our Windows 10 PC. Communicating through our … Read more